Home Home Products Operating Manuals FAQS Customer Feedback Form
Shortridge Instruments, Inc.

FlowHood CFM-850L

BACKPRESSURE COMPENSATED AIR BALANCE SYSTEM

CFM-850L

The FlowHood is a much more convenient alternative to time-consuming multiple velocity readings across air diffusers, as this instrument eliminates the need for the calculations necessary to convert the average velocity into air flow.

CFM-850L - This model includes the meter, the base metering section, various top sizes and carrying case.

It measures pitot tube velocity, static pressure and temperature, in addition to airflow.


The FlowHood CFM-88L air balance system may also be ordered as a model CFM-850L with the multipurpose ADM-850L AirData Multimeter.

UPGRADE LATER

When more functionality is required, such as velocity, memory or auto-read, the CFM-88L meter may be converted into an ADM-850L, ADM-860C, or ADM-870C.

Accessories for measuring air velocity, pressure, and temperature may be ordered as needed.

FLOWHOOD FAQS

HOW DO THE FLOWHOOD MODELS DIFFER?


FLOWHOOD MODEL CFM-88L
    The FlowHood CFM-88L is used for air flow and temperature measurement only, and comes complete with a CFM-88L meter and an air capture hood kit.
FLOWHOOD MODEL CFM-850L
    The FlowHood Model CFM-850L has added functions for pitot tube air velocity and differential pressure.
FLOWHOOD KITS
    FlowHood Kits may be ordered with any combination of top sizes. Special top sizes will be designed to order upon request.

More About FlowHoods...


The FlowHood CFM-88L is used for air flow, temperature and absolute pressure measurement only, and comes complete with a CFM-88L meter, TemProbe and an air capture hood. The FlowHood Model CFM-850L has added functions for pitot tube air velocity, differential pressure, and temperature measurement.

FlowHood kits are available in a combination of top sizes. Custom top sizes will be designed to order upon request.

FlowHood

The FlowHood is a much more convenient alternative to time-consuming multiple velocity readings across air diffusers, as this instrument eliminates the need for the calculations necessary to convert the average velocity into air flow.

The AirData Multimeter utilizes the Series 8400 FlowHood Kit for backpressure compensated measurement of air flow. The FlowHood unit captures and directs the air flow from an outlet, or inlet, across the highly sensitive flow sensing manifold within the FlowHood base.


Please feel free to call our sales department if you have any questions regarding delivery, prices, or special needs.